Signal gate valves are commonly used in automatic sprinkler fire pipeline systems to monitor water supply pipelines and remotely indicate valve opening. By turning the handwheel, the thread between the handwheel and the valve stem can be controlled to advance or retract, and the valve plate connected to the valve stem can be raised or lowered to achieve the purpose of opening and closing.
Product Consultation

   Product Details

1、 Working principle

Signal gate valves are commonly used in automatic sprinkler fire pipeline systems to monitor water supply pipelines and remotely indicate valve opening. By turning the handwheel, the thread between the handwheel and the valve stem can be controlled to advance or retract, and the valve plate connected to the valve stem can be raised or lowered to achieve the purpose of opening and closing.

 

2、 Product Introduction

The valve body material of the signal gate valve produced by our company is ductile iron, the valve plate material is ductile iron coated with rubber, the sealing material is EPDM, and the shaft material is chrome plated 45 # steel. The signal gate valve is equipped with a signal device that emits an electrical signal when the valve plate is released from the fully closed position. The production standard for signal gate valves is GB5135.6 Automatic Sprinkler Fire Extinguishing System Part 6: General Valves.

 

3、 Product advantages and uses

In addition to the advantages of elastic seat sealed gate valves, fire signal gate valves also have fast and reliable opening and closing, and can intuitively display the degree of valve opening, so as to distinguish the degree of valve opening from a distance and take corresponding measures in a timely manner. The fire signal gate valve is installed at both ends of the alarm valve group or at the inlet of each branch pipe of the system. When repairing the alarm valve group or pipeline network, close it. The signal gate valve is equipped with a signal device that can emit electrical signals to display the opening and status of the valve plate.

 

4、 Product technical parameters, installation dimensions

Applicable media: water, oil, gas, etc

Suitable temperature: 0-80 ℃

Signal power supply: DC24V, 3A

Nominal operating pressure: 1.6MPa

Test standard: GB13927 AP1598


6、 Installation and maintenance instructions

a. There should be a certain space around the signal gate valve for easy installation, maintenance, and operation;

b. During transportation and installation of signal gate valves, violent collisions should be avoided as much as possible to prevent damage to the sealing surface and micro switches, which may affect their sealing performance and the normal operation of the electrical signal system;

c. Do not disassemble or adjust the signal gate valve before and after installation;

d. After the installation of the signal gate valve, the valve plate should be fully opened and the inner cavity of the pipeline should be flushed clean before the pipeline undergoes a sealing pressure test. Otherwise, it may cause the valve plate to not close tightly. The closed or open state should be locked.


Price inquiry
Please enter your mobile phone number
confirm
close

Copyright ◎ Beixiao Safety Equipment (Beijing) Co., Ltd. Beijing ICP No. 18016324

Beijing Public Security Registration No. 11011502003374

Fax: 010-61245283

Website: www.bx119.cn

Postal Code: 102600

E-mail:bx  119@163.com

Address: Room A813, 8th Floor, Building 6, 

No. 15 Jinyuan Road, Daxing District, Beijing


Monday to Friday 

9:00-12:00 13:30-18:00

Online consultation

010-61244746

Signal gate valve
Trench ZSXF-(50-200)-(G)
Signal gate valves are commonly used in automatic sprinkler fire pipeline systems to monitor water supply pipelines and remotely indicate valve opening. By turning the handwheel, the thread between the handwheel and the valve stem can be controlled to advance or retract, and the valve plate connected to the valve stem can be raised or lowered to achieve the purpose of opening and closing.
Product Consultation

   Product Details

1、 Working principle

Signal gate valves are commonly used in automatic sprinkler fire pipeline systems to monitor water supply pipelines and remotely indicate valve opening. By turning the handwheel, the thread between the handwheel and the valve stem can be controlled to advance or retract, and the valve plate connected to the valve stem can be raised or lowered to achieve the purpose of opening and closing.

 

2、 Product Introduction

The valve body material of the signal gate valve produced by our company is ductile iron, the valve plate material is ductile iron coated with rubber, the sealing material is EPDM, and the shaft material is chrome plated 45 # steel. The signal gate valve is equipped with a signal device that emits an electrical signal when the valve plate is released from the fully closed position. The production standard for signal gate valves is GB5135.6 Automatic Sprinkler Fire Extinguishing System Part 6: General Valves.

 

3、 Product advantages and uses

In addition to the advantages of elastic seat sealed gate valves, fire signal gate valves also have fast and reliable opening and closing, and can intuitively display the degree of valve opening, so as to distinguish the degree of valve opening from a distance and take corresponding measures in a timely manner. The fire signal gate valve is installed at both ends of the alarm valve group or at the inlet of each branch pipe of the system. When repairing the alarm valve group or pipeline network, close it. The signal gate valve is equipped with a signal device that can emit electrical signals to display the opening and status of the valve plate.

 

4、 Product technical parameters, installation dimensions

Applicable media: water, oil, gas, etc

Suitable temperature: 0-80 ℃

Signal power supply: DC24V, 3A

Nominal operating pressure: 1.6MPa

Test standard: GB13927 AP1598


6、 Installation and maintenance instructions

a. There should be a certain space around the signal gate valve for easy installation, maintenance, and operation;

b. During transportation and installation of signal gate valves, violent collisions should be avoided as much as possible to prevent damage to the sealing surface and micro switches, which may affect their sealing performance and the normal operation of the electrical signal system;

c. Do not disassemble or adjust the signal gate valve before and after installation;

d. After the installation of the signal gate valve, the valve plate should be fully opened and the inner cavity of the pipeline should be flushed clean before the pipeline undergoes a sealing pressure test. Otherwise, it may cause the valve plate to not close tightly. The closed or open state should be locked.



Price inquiry
Please enter your mobile phone number
confirm
close
Online consultation

Copyright ©  Beixiao Safety Equipment (Beijing) Co., Ltd. Beijing ICP No. 18016324

Beijing Public Security Registration No. 11011502003374

Fax: 010-61245283

Website: www.bx119.cn

Postal Code: 102600

E-mail:bx  119@163.com

Address: Room A813, 8th Floor, Building 6, 

No. 15 Jinyuan Road, Daxing District, Beijing



010-61244746

Monday to Friday 9:00-12:00 13:30-18:00

   
 
X